Rheumatology 1999; 38: 1269-1271
© 1999 British Society for Rheumatology
Ultrasonic measurement of the thickness of human articular cartilage in situ
Biomechanics Laboratory, Rheumatology & Rehabilitation Research Unit, Research School of Medicine, University of Leeds, 36 Clarendon Road, Leeds LS2 9NZ, UK
Correspondence to:
B. B. Seedhom, Biomechanics Laboratory, Rheumatology and Rehabilitation Research Unit, University of Leeds, 36 Clarendon Road, Leeds LS2 9NZ, UK.
Objective. The objective of the present study was to explore the possibility of using the ultrasonic pulseecho technique for the non-invasive measurement of cartilage thickness in situ during a joint arthroscopic examination. The accuracy of the ultrasonic measurement was assessed in vitro against that of an established needling technique which is destructive.
Methods. The velocity of sound in articular cartilage was measured in an in vitro study of one set of ipsilateral human ankle and hip joints at 69 test sites. Its variability was determined.
Results. The velocity of sound in human articular cartilage measured in situ varied widely (14192428 m/s; mean: 1892 m/s; S.D. 183 m/s) and therefore the error in the thickness of cartilage obtained from ultrasonic measurement based upon a constant velocity of sound could be as large as 33.6% (mean 7.38%; S.D. 6.25%).
Conclusions. The ultrasonic pulseecho technique is not accurate for the measurement of the thickness of cartilage in situ. An alternative (albeit minimally invasive) would be the needling technique. This requires the development of a specialized probe.
KEY WORDS: Cartilage, Ultrasound, Thickness
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
R. W. Mann Comment on 'ultrasonic measurement of the thickness of human articular cartilage in situ' by Yao and Seedhom Rheumatology, July 1, 2001; 40(7): 829 - 831. [Full Text] [PDF] |
||||