Skip Navigation

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (12)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Maillefert, J. F.
Right arrow Articles by Dougados, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Maillefert, J. F.
Right arrow Articles by Dougados, M.
Related Collections
Right arrow Osteoarthritis and Cartilage
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Rheumatology 2002; 41: 148-152
© 2002 British Society for Rheumatology


Original papers

Relevant change in radiological progression in patients with hip osteoarthritis. II. Determination using an expert opinion approach

J. F. Maillefert1,4, M. Nguyen1, A. Gueguen2, L. Berdah3, M. Lequesne5, B. Mazières6, E. Vignon7 and M. Dougados1,

1 René Descartes University, Cochin Hospital, Institut de Rhumatologie, Paris,
2 INSERM U88, St Maurice Hospital, Paris,
3 NEGMA Laboratories, Toussus le Noble,
4 General Hospital, Dijon,
5 Leopold Bellan Hospital, Paris,
6 Rangueil Hospital, Toulouse and
7 Lyon-Sud Hospital, Pierre Bénite, France

Aim. To determine the minimum clinically important difference (MCID) in joint space width (JSW) progression in patients with hip osteoarthritis (OA), based upon evaluation by a panel of clinical experts as a gold standard.

Methods. A sample of 298 patients with hip OA was selected from a multicentre, prospective, longitudinal, 3-yr follow-up study. A pelvic radiograph was obtained at entry and after 3 yr. For each film, the narrowest JSW was measured using a 0.1-mm graduated magnifying glass. The difference between baseline and 3-yr follow-up JSW was calculated. Two senior rheumatologists, who were experts in osteoarthritis, evaluated each pair of films and noted whether a clinically relevant deterioration in osteoarthritis stage occurred at 3 yr compared with baseline. Interobserver reliabilities were evaluated using the {kappa} coefficient and proportions of agreements. Then, for each measured difference in JSW (0.1 mm per 0.1 mm), the sensitivity and specificity for MCID, defined as the assessment of expert 1, expert 2 or a combination of both, were calculated. This allowed us to obtain, from graphic representations of the correct classification probabilities, the best measured JSW threshold, with the maximal true positive and the minimal false positive results.

Results. The mean measured change in JSW was -0.63±0.74 mm. Experts 1 and 2 considered the decrease in JSW to be clinically relevant in 122 (40.9%) and 100 pairs (33.6%) respectively. The proportion of agreements between the experts was 79.9%, with a {kappa} coefficient of 0.572. The best measured JSW threshold was -0.4 mm for expert 1, expert 2 and the combination of both; sensitivity and specificity were 0.75 and 0.8, 0.71 and 0.72, and 0.75 and 0.7 respectively.

Conclusion. This study suggests that a change of at least 0.4 mm in the radiological JSW could be considered clinically relevant. Other studies using other sets of patients and other methods are needed for validation.

KEY WORDS: Minimum clinically important difference, Hip osteoarthritis, Joint space width, Outcome measure.

Correspondence to: M. Dougados, Institut de Rhumatologie, Cochin Hospital, 27 rue du Faubourg Saint Jacques, 75014 Paris, France.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.