Skip Navigation

Rheumatology 2005 44(Supplement 3):iii16; doi:10.1093/rheumatology/keh759
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Dhar, A.
Right arrow Articles by Docken, W. P.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Dhar, A.
Right arrow Articles by Docken, W. P.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?




Supplement Article

PP6. OUTCOMES OF PATIENTS UNDERGOING TEMPORAL ARTERY BIOPSY OF LESS THAN 1 CM LENGTH FOR SUSPECTED GIANT CELL ARTERITIS

A. Dhar, D. Bienfang, K. Batra, L. Chibnik, A. H. Fossel, M. H. Liang, E. H. Noss, R. Padera and W. P. Docken

Brigham and Women's Hospital, Boston, MA, USA

Background: The cornerstone of diagnosis in giant cell arteritis (GCA) is temporal artery biopsy (TAB). The conventional wisdom is that long length biopsies be obtained but no consensus exists on optimum length of biopsy.

Objective: To examine the relationship between TAB length and 1 year outcomes in patients with suspected GCA.

Methods: Clinical data was abstracted from the medical record on all patients undergoing TAB from 1994–2003. Data collected included age, gender, race, length of biopsy, histopathologic findings and outcomes including visual loss, stroke, myocardial infarction, polymyalgia rheumatica and death at 1 year. GCA diagnosis at 1 year was defined on clinical grounds or positive biopsy. False negative rate was defined as a negative biopsy but GCA at 1 year due to a repeat positive biopsy or clinical grounds.

Results: 200 patients with TAB had complete follow-up data. The mean age was 69.6±11.0 years and 166/200 (83.3%) were females. The TAB length ranged from 0.1–2.4 cm, with a mean of 0.73±0.31 cm. 146/200 (73%) had a negative biopsy and 54/200 (27%) had a positive biopsy. There was no significant difference in mean biopsy length between patients with a positive (0.80±0.29) and negative biopsy (0.71±0.32, p = 0.0999). 2/143 (1.4%) patients had a false negative biopsy. Their TAB lengths were 0.6cm and 0.7cm, which approximated the mean length for the group. Taking a <1 cm biopsy resulted in no adverse clinical events.

Conclusion: Our study suggests that TAB length of <1 cm has good sensitivity, is safe and associated with no untoward events.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.