Skip Navigation

This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (19)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Auleley, G.-R.
Right arrow Articles by Ravaud, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Auleley, G.-R.
Right arrow Articles by Ravaud, P.
Related Collections
Right arrow Osteoarthritis and Cartilage
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Rheumatology 2001; 40: 414-419
© 2001 British Society for Rheumatology

Measurement of joint space width in hip osteoarthritis: influence of joint positioning and radiographic procedure

G.-R. Auleley, A. Duche, J.-L. Drape1, M. Dougados and P. Ravaud2,

Clinique de Rhumatologie and
1 Service de Radiologie B, Université Paris V-René Descartes, Faculté de Médecine Cochin Port-Royal, Hôpital Cochin, AP-HP, Paris and
2 Université Paris VII, Faculté de Médecine Xavier Bichat and Départment de Biostatistique et d'Epidémiologie Clinique, Hôpital Bichat-Claude Bernard, AP-HP, Paris, France


    Abstract
 Top
 Abstract
 Introduction
 Patients and methods
 Results
 Discussion
 References
 
Objectives. We assessed the influence of patient positioning and radiographic procedure, and defined a smallest detectable difference (SDD) in hip osteoarthritis (OA).

Methods. OA hip patients each had a standardized pelvic radiograph and, 5 min later, a modified pelvic radiograph with the feet internally rotated 5° (part 1 of the study), the X-ray beam centred on the umbilicus (part 2), or another standardized pelvic radiograph (part 3).

Results. Corresponding mean differences in joint space width (JSW) measurements (limits of agreement) between views were +0.03 (-0.53 to +0.59), -0.31 (-1.15 to +0.53) and -0.02 (-0.48 to +0.44) mm. The two views differed significantly in mean JSW in part 2 of the study (P=1.6x10-4), but not in part 1 (P=0.375) and part 3 (P=0.580). The SDD estimate was 0.46 mm.

Conclusions. Modifying the X-ray beam and foot rotation increases variability in JSW measurements. Use of urograms to evaluate radiological progression should be avoided. A change greater than 0.46 mm could define radiological hip OA progression.

KEY WORDS: Hip, Joint space width, Osteoarthritis, Radiographic measurement, Smallest detectable difference.


    Introduction
 Top
 Abstract
 Introduction
 Patients and methods
 Results
 Discussion
 References
 
The plain radiograph is a readily available, safe and cost-effective tool for diagnosing and assessing the progression of osteoarthritis (OA) [1, 2]. In both epidemiological studies and clinical trials, the best established method of assessing OA progression is by cartilage loss as measured by joint space width (JSW) at the narrowest point on plain radiographs [2, 3]. Radiographic OA progression is slow [4], varying from 0.1 to 0.6 mm/yr [5–7].

However, reliable assessment of OA progression requires reproducible radiographs to be obtained on successive visits [8, 9]. Numerous sources of variability can modify JSW measurements and compromise their reliability [811]. Such variability has been widely studied in the knee. Foot rotation has been found to be related to measurement error [10] and to significant change in JSW measurements compared with ideal joint positioning [11]. On the other hand, changes associated with directing the X-ray beam below the centre of the joint space do not appear to be significant [10].

Such changes have been less studied in the hip, although differences in patient positioning and radiographic procedure remain in the assessment of radiological hip OA. First, pelvic or hip radiographs can be performed with the patient's feet internally rotated by an amount ranging from 5° to 25° [2, 1218]. Second, hip JSW is sometimes measured on i.v. urograms [1923], in which the X-ray beam is centred approximately 10 cm higher than for standard anteroposterior pelvic radiographs. Although the minimum joint space in the hip may be altered by modifying foot rotation [24] or X-ray beam centring [16], the effects of these modifications on JSW measurements in hip OA are largely unknown. Thus, the aims of this study were (i) to assess the influence of internal foot rotation and X-ray beam centring on JSW measurements, and (ii) to determine a cutoff that allows a definition of radiological hip OA progression beyond the variability related to radiographic procedure and measurement process.


    Patients and methods
 Top
 Abstract
 Introduction
 Patients and methods
 Results
 Discussion
 References
 
Patients
Patients of both sexes with symptomatic hip OA attending the Department of Rheumatology and willing to participate were included in this study. Hip OA was determined by the presence of pain and at least two of the following factors: radiographic osteophytes, radiographic joint space narrowing and an erythrocyte sedimentation rate of <=20 mm/h [25]. Patients were excluded if they had secondary hip OA, defined by a history of hip fracture, or the presence of calcium deposition in the hip joint, osteonecrosis, inflammatory rheumatic disease, Paget's disease, infectious joint disease, or other hip diseases [25].

Radiography procedure
Pelvic radiographs were taken in three successive groups of 20 consecutive patients. Each patient had two pelvic radiographs taken 5 min apart. Radiographs of a given patient were taken by the same technician in a single radiology unit, using a fast screen, cassette film and a standardized procedure. The cassette was adjusted in the holder so that the midline of the film was in alignment with the midheel line. The focus-to-film distance was 100 cm. Anteroposterior, standardized radiographs including both hips were taken in the supine position with the X-ray beam vertical, perpendicular to the table. To obtain a constant and reproducible foot position, the inner side of each foot was aligned on a study-specific V-shaped positioning frame, positioned on the table, with the backs of the patient's heels lying directly on the table. For these standardized radiographs, the X-ray beam was centred 2 cm above the superior aspect of the symphysis pubis and the feet were internally rotated 15° [2, 1215] using the V-shaped positioning frame.

The first part of the study evaluated the influence of internal foot rotation. Patients first had a standardized radiograph taken with the feet internally rotated 15°; 5 min later a modified radiograph was taken with the feet internally rotated 5° using another study-specific V-shaped positioning frame. The other parameters (patient positioning and radiograph procedure) were unchanged.

The second part of the study evaluated the influence of X-ray beam centring. Patients had a standardized radiograph taken with the X-ray beam centred 2 cm above the superior aspect of the symphysis pubis; 5 min later a modified radiograph was taken with the X-ray beam centred on the umbilicus. The other parameters (patient positioning and radiograph procedure) were unchanged.

The third part of the study (referred to as the standardized part) evaluated the reproducibility of pelvic radiographs. Pelvic radiographs were taken twice for each patient using a standardized procedure.

Radiographic assessment
Both hips of a given patient were eligible. Hips with Kellgren and Lawrence grade 2 or 3 [26] were included. In each part of the study, the two radiographs of a single patient were placed side by side on a light box and landmarks for measurements were drawn by the person who read the radiograph. The landmarks consisted of two points at the narrowest point: one was on the distal margin of the condylar cortex for the femoral surface, and the other was on the margin of the bright radio-dense band of the subchondral cortex in the floor of the articular fossa for the acetabulum. The patient's identification and the type of view were then masked with adhesive tape. The patient's identification was replaced by a random code number.

Radiographs were assessed by a single reader (GRA). The interbone distance determined by the landmarks was measured in millimetres using a 0.1 mm graduated magnifying glass laid directly over the radiograph.

Statistical analysis
In order to determine the influence of foot rotation and X-ray beam centring on JSW measurements, the magnitude of changes related to each modified view was assessed with the graphic analysis method of Bland and Altman [2729]. According to this analysis, differences between pairs of JSW measurements of the same joint of a given patient were plotted against their corresponding mean, including the limits of agreement defined as dmean±2 S.D., where dmean is the mean difference and S.D. is the standard deviation of the difference. Differences between pairs of JSW measurements of the same joint on the standardized and modified radiographs of a given patient were plotted against their corresponding mean. For each part of the study, a graph was plotted, including the limits of agreement defined as above.

The reproducibility of standardized pelvic radiographs was also assessed using the graphic analysis method of Bland and Altman [2729]. Differences between pairs of JSW measurements of the same joint of a given patient were plotted against their corresponding mean, including the limits of agreement. Such differences between JSW measurements on standardized radiographs repeated 5 min apart reflected the variability inherent in the radiographic procedure and the measurement process. Thus, to be considered a statistically relevant progression, any difference between serial radiographs had to be greater than this variability. The smallest detectable difference (SDD) was based on the reproducibility of radiographic measurement (i.e. related to repeating the standardized radiographic procedure and measurement process) in hip OA. For a risk of {alpha}=5%, the SDD in radiological progression in hip OA for one individual was defined as 2 S.D. of the difference between pairs of standardized radiographs [30, 31].

In addition, means of pairs of JSW measurements were compared in each part of the study using the paired t-test. We used a two-tailed formulation, and P<0.05 was considered statistically significant.


    Results
 Top
 Abstract
 Introduction
 Patients and methods
 Results
 Discussion
 References
 
Twenty patients were included in each part of this study. Table 1Go summarizes the demographic and radiological characteristics of the patients.


View this table:
[in this window]
[in a new window]
 
TABLE 1. Demographic and radiological characteristics of patients with hip osteoarthritis assessed for the influence of X-ray beam centring and internal foot rotation on joint space width measurement, and reproducibility of standardized pelvic radiographs

 
Thirty-seven hips were available for assessment in the foot rotation part of this study. An artificial hip in one patient and one hip with Kellgren and Lawrence grade 1 in two patients were excluded. Mean (S.D.) of JSW was 3.10 (1.01) mm on the standardized pelvic radiograph. Thirty-nine hips were available for assessment in the X-ray beam centring part of the study. One hip with JSW=0 mm was excluded. Mean (S.D.) of JSW was 3.17 (0.81) mm on the standardized pelvic radiograph. Thirty- seven hips were available in the standardized part of the study. One artificial hip in one patient, one hip with JSW=0 mm, and one hip with Kellgren and Lawrence grade were excluded. Mean (S.D.) of JSW was 3.39 (1.02) mm.

Influence of internal foot rotation
Mean (S.D.) JSW was 3.07 (1.01) mm in pelvic radiographs 5° internal foot rotation, i.e. it was of a similar magnitude to that of pelvic radiographs with 15° internal foot rotation. The two views did not differ significantly in JSW measurements (P=0.375). Thus, internal foot rotation at 5° did not modify JSW on pelvic radiographs performed in the supine position. The difference in JSW between 15° and 5° internal foot rotation was 0.03 mm on average (Table 2Go) but varied from -0.70 mm to +0.60 mm. Absolute differences between the two views in JSW measurements >=0.50 mm were observed in four of 37 cases. No specific relationship existed between the difference and the mean (Fig. 1AGo).


View this table:
[in this window]
[in a new window]
 
TABLE 2. Mean differences in JSW (mm) between a standardized pelvic radiograph and either a pelvic radiograph with 5° internal foot rotation (foot rotation part of study) or X-ray beam centring on the umbilicus (X-ray beam centring part of study), and between two standardized pelvic radiographs (standardized part of study). Differences are calculated on JSW measurements as values on both standardized radiographs, and as values on standardized radiographs minus modified radiographs when appropriate

 


View larger version (19K):
[in this window]
[in a new window]
 
FIG. 1. (A) Differences in the measurement of JSW (mm) between the standardized pelvic radiographs performed with 15° internal foot rotation and pelvic radiographs performed with 5° internal foot rotation (15° minus 5°) plotted against mean JSW measurement. (B) Differences in the measurement of JSW (mm) between the standardized pelvic radiographs performed with the X-ray beam centred 2 cm above the superior aspect of the symphysis pubis and radiographs performed with the X-ray beam centred on the umbilicus (pubis minus umbilicus) plotted against mean JSW measurement. (C) Differences in the measurement of JSW (mm) between two standardized pelvic radiographs performed with 15° internal foot rotation and the X-ray beam centred 2 cm above the superior aspect of the symphysis pubis plotted against mean JSW measurement. Limits of agreement correspond to mean±2 S.D.

 

Influence of X-ray beam centring
On radiographs performed with the X-ray beam centred on the umbilicus, mean (S.D.) JSW was 3.48 (0.90) mm. JSW increased on average by 10.26% (12.99%) in this view compared with the standardized pelvic radiographs. The two views differed significantly in JSW measurements (P=1.6x10-4). The difference in JSW between these views was -0.31 mm on average (Table 2Go) but varied from -1.60 mm to +0.60 mm. Absolute differences between the two views in JSW measurements >=0.50 mm were observed in 10 of 39 cases. No specific relationship existed between the difference and the mean (Fig. 1BGo).

Reproducibility of pelvic radiographs and SDD
JSW measurements did not differ (P=0.580) between the two standardized radiographs [3.39 (1.02) and 3.41 (1.02) mm respectively]. The absolute difference in JSW between repeated radiographs was 0.02 mm on average (Table 2Go) but varied from -0.40 mm to +0.80 mm. Absolute differences in JSW measurements >=0.50 mm were observed in one of 37 cases between standardized repeated radiographs. No specific relationship existed between the difference and the mean (Fig. 1CGo). The estimated radiological progression in hip OA as defined by the SDD for one individual, i.e. twice the S.D. of the difference between standardized radiographs, was 0.46 mm.


    Discussion
 Top
 Abstract
 Introduction
 Patients and methods
 Results
 Discussion
 References
 
In this study, changing foot rotation by 10° did not change JSW significantly on pelvic radiographs. In contrast, centring the X-ray beam on the umbilicus instead of on the superior aspect of the symphysis pubis resulted in an average increase in JSW of about 10%. Radiological progression based on analysis of radiographic reproducibility was 0.46 mm in this population, using a defined standardized radiographic procedure and measurement process, with this particular reader and measurement instrument.

Differences in JSW measurements related to modification of foot rotation were insufficient (0.03 mm) to be detectable with the measuring instrument we used. Moreover, the effect of foot rotation seems to be less in the hip than in the knee joint [10, 11]. It is thought that internal foot rotation applies a load to the articular hip surfaces [14], possibly by tightening the powerful lateral rotator muscles of the hip joint that drive the femoral head internally into the acetabulum [24]. Our findings in this study suggest that a 10° difference in internal foot rotation does not induce bias in JSW measured on pelvic radiographs of patients with hip OA, as assessed by the mean difference. However, we cannot exclude the possibility that a greater difference in foot rotation induces a significant bias, as suggested by Buckland-Wright [24]. This author studied nine cadavers and reported that the joint space of the hip was narrower in radiographs obtained with the foot rotated internally than with the foot in the neutral position. However, our results suggest that a 10° difference in internal foot rotation increases the variability in JSW measurement as assessed by the S.D. of the differences (Fig. 1AGo and C and Table 2Go).

More interesting was the effect on JSW measurements of centring the X-ray beam on the umbilicus. In the knee, displacement of the X-ray beam direction led to conflicting results [10, 11]. In the hip, however, the results of Conrozier et al. [16] suggest that such a displacement of the X-ray beam from the hip joint to 2 cm above the symphysis pubis can influence JSW measurement. Nevertheless, their study did not directly compare the two different patient groups, one having hip radiographs and the other pelvic radiographs. In this study, we evaluated the effect of two X-ray beam centrings, both away from the hip joint, on the same patient group. The increase in JSW on radiographs performed with the X-ray beam centred on the umbilicus compared with the standardized pelvic radiograph may be due to modifications induced by the downward inclination of the X-ray exploring the joint space.

Our study assessed the reproducibility of the standardized pelvic radiograph in patients in stable condition (two radiographs 5 min apart). The cutoff observed in this study (0.46 mm) is smaller than that reported in the knee (0.62 mm) [30]. Greater variation in the radiographic process in the knee [11] may explain this difference. This cutoff is indeed close to that (0.56 mm) reported by Dougados et al. [32] for hip OA despite the use of a different approach (two radiographs 1 yr apart).

A limitation of this study is that the radiographs were performed in the supine position. Although JSW measurements made on standing and supine knee radiographs differ [3336], results in the hip remain contradictory [16, 37, 38]. However, we previously reported no significant difference in JSW measurement between the two views. In addition, technically better images may be obtained with supine than with standing pelvic radiographs, particularly in obese patients. Another limitation is that we did not compare the greatest possible degrees of rotation that can be used in radiography of the hip, i.e. 5° and 25°. Such a range of rotation may result in significant differences in JSW measurements. However, most guidelines recommend 15° internal foot rotation to radiograph the hip joint [8, 12, 14, 15].

In longitudinal studies, reproducible radiographs taken at different times allow reliable assessment of OA progression. For this reason, the sources of variability in JSW measurement must be minimized. First, we recommend using a positioning frame for pelvic radiographs in order to obtain a fixed degree of internal foot rotation, e.g. 15° in studies measuring JSW, instead of allowing a varying degree of rotation, e.g. 15±5°. Although our study does not support a statistically significant change in mean JSW measurement due to modifications in internal foot rotation, such a change remains possible [24]. However, our study does suggest that the difference in internal foot rotation increases the variability of JSW measurements in the hip. Thus, using a standardized positioning frame will assure that the same rotation is used in repeated radiographs in a given patient and across studies. Secondly, we do not recommend evaluating radiological progression in hip OA using urograms. Pelvic radiographs should be taken with the X-ray beam centred precisely on the superior aspect of the symphysis pubis.

We have assessed the influence of some sources of variability in JSW measurement in hip OA and defined an SDD in radiological hip OA progression. These results need to be confirmed. Long-term longitudinal studies using standardized procedures as recommended in this study are also needed.


    Notes
 
Correspondence to: P. Ravaud, Clinique de Rhumatologie, Hôpital Cochin, 27 rue du faubourg Saint-Jacques, 75014 Paris, France Back


    References
 Top
 Abstract
 Introduction
 Patients and methods
 Results
 Discussion
 References
 

  1. Jewell FM, Watt I, Doherty M. Plain radiographic features of osteoarthritis. In Brandt KD, Doherty M, Lohmander LS, eds. Osteoarthritis. New York: Oxford University Press, 1998:217–37.
  2. Recommendations from a task force of the Osteoarthritis Research Society: Design and conduct of clinical trials in patients with osteoarthritis. Osteoarthritis Cartilage1996;4:217–43.[Web of Science][Medline]
  3. Jonsson K, Buckwalter K, Helvie M, Niklason L, Martel W. Precision of hyaline cartilage thickness measurements. Acta Radiol1992;33:234–9.[Medline]
  4. Spector TD, Dacre JE, Harris PA, Huskisson EC. Radiological progression of osteoarthritis: an 11 year follow up study of the knee. Ann Rheum Dis1992;51: 1107–10.[Abstract/Free Full Text]
  5. Dougados M, Gueguen A, Nguyen M et al. Longitudinal radiologic evaluation of osteoarthritis of the knee. J Rheumatol1992;19:378–84.[Web of Science][Medline]
  6. Lequesne M. Quantitative measurements of joint space during progression of osteoarthritis: Chondrometry. In: Kuettner KE, Goldberg V, eds. Osteoarthritic disorders. Illinois: American Academy of Orthopedic Surgery, 1995:427–44.
  7. Kirwan JR, Cushnaghan J, Dacre J et al. Progression of joint space narrowing in knee [abstract]. Arthritis Rheum1992;35(Suppl.):B103.
  8. Buckland-Wright JC. Quantitative radiography of osteoarthritis. Ann Rheum Dis1994;63:268–75.
  9. Ravaud P, Dougados M. Radiographic assessment in osteoarthritis. J Rheumatol1997;24:786–91.[Medline]
  10. Lynch JA, Buckland-Wright C, MacFarlane DG. Precision of joint space width measurement in knee osteoarthritis from digital image analysis of high definition macroradiographs. Osteoarthritis Cartilage1993;l:209–18.
  11. Ravaud P, Auleley G-R, Chastang C et al. Knee joint space width measurement: An experimental study of the influence of radiographic procedure and joint positioning. Br J Rheumatol1996;35:761–6.[Abstract/Free Full Text]
  12. Buckland-Wright C, Scott Jr WW, Peterfy C. Radiographic imaging techniques. In Brandt KD, Doherty M, Lohmander LS, eds. Osteoarthritis. New York: Oxford University Press, 1998:572–4.
  13. Buckland-Wright C. Protocols for radiography. In Brandt KD, Doherty M, Lohmander LS, eds. Osteoarthritis. New York: Oxford University Press, 1998:578–80.
  14. Dieppe P, Altman RD, Buckwalter JA et al. Standardization of methods used to assess the progression of osteoarthritis of the hip or knee joints. In: Kuettner KE, Goldberg VM, eds. Osteoarthritis disorders. Rosemont, IL: American Academy of Orthopedic Surgeons, 1994: 481–96.
  15. Dieppe PA. Recommended methodology for assessing the progression of osteoarthritis of the hip and knee joints. Osteoarthritis Cartilage1995;3:73–7.[Web of Science][Medline]
  16. Conrozier T, Lequesne MG, Tron AM, Mathieu P, Berdah L, Vignon B. The effects of position on the radiographic joint space in osteoarthritis of the hip. Osteoarthritis Cartilage1997;5:17–22.[Medline]
  17. Hansson G, Jerrer R, Sanders SM, Wallin J. Radiographic assessment of coxarthrosis following slipped capital femoral epiphysis: A 32-year follow-up study of 151 hips. Acta Radiol1993;34:117–23.[Medline]
  18. Resnick D, Niwayama G. Diagnosis of bone and joint disorders. Vol. I. Philadelphia: W.B. Saunders,1988:40.
  19. Croft P, Cooper C, Wickham C, Coggon D. Defining osteoarthritis of the hip for epidemiologic studies. Am J Epidemiol1990;132:514–22.[Abstract/Free Full Text]
  20. Croft P, Cooper C, Wickham C, Coggon D. Osteoarthritis of the hip and acetabular dysplasia. Ann Rheum Dis1991;50:308–10.[Abstract/Free Full Text]
  21. Croft P, Cooper C, Wickham C, Coggon D. Is the hip involved in generalized osteoarthritis? Br J Rheumatol1992;31:325–8.[Abstract/Free Full Text]
  22. Lau EMC, Lin F, Lam D, Silman A, Croft P. Hip osteoarthritis and dysplasia in Chinese men. Ann Rheum Dis1995;54:965–9.[Abstract/Free Full Text]
  23. Smith RW, Egger P, Coggon D, Cawley MID, Cooper C. Osteoarthritis of the hip joint and acetabular dysplasia in women. Ann Rheum Dis1995;54:179–81.[Abstract/Free Full Text]
  24. Buckland-Wright C. Quantitation of radiographic changes. In: Brandt KD, Doherty M, Lohmander LS, eds. Osteoarthritis. New York: Oxford University Press, 1998:459–72.
  25. Altman RD. The classification of osteoarthritis. J Rheumatol1995 (Suppl. 53);22:42–3.
  26. Kellgren JH, Lawrence JS. Radiological assessment of osteo-arthrosis. Ann Rheum Dis1957;16:494–502.[Free Full Text]
  27. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet1986;i:307–10.
  28. Bland JM, Altman DG. Comparing two methods of clinical measurement: a personal history. Int J Epidemiol1995;24(Suppl. 1):S7–14.[Medline]
  29. Bland JM, Altman DG. Measurement error. Br Med J1996;313:744.[Free Full Text]
  30. Ravaud P, Giraudeau B, Auleley G-R et al. Variability in knee radiographing: implication for definition of radiological progression in medial knee osteoarthritis. Ann Rheum Dis1998;57:624–9.[Abstract/Free Full Text]
  31. Ravaud P, Giraudeau B, Auleley G-R, Edouard-Noël R, Dougados M, Chastang C. Smallest detectable change over time in continuous structural outcome measures: application to radiological change in knee osteoarthritis. J Clin Epidemiol1999;52:1225–30.[Web of Science][Medline]
  32. Dougados M, Gueguen A, Nguyen M et al. Radiological progression of hip osteoarthritis: definition, risk factors and correlations with clinical status. Ann Rheum Dis1996;55:356–62.[Abstract/Free Full Text]
  33. Altman RD, Fries JF, Bloch DA et al. Radiographic assessment of progression in osteoarthritis. Arthritis Rheum1987;30:1214–25.[Web of Science][Medline]
  34. Ahlback S. Osteoarthritis of the knee: a radiographic investigation. Acta Radiol1968;277(Suppl.):7–72.
  35. Leach RE, Gregg T, Siber FJ. Weight-bearing radiography in osteoarthritis of the knee. Radiology1970; 97:265–8.[Medline]
  36. Buckland-Wright JC, Macfarlane DG, Lynch JA, Jasani MK, Bradshaw CR. Joint space width measures cartilage thickness in osteoarthritis of the knee: high resolution plain film and double contrast macroradiographic investigation. Ann Rheum Dis1995;54:263–8.[Abstract/Free Full Text]
  37. Auleley G-R, Rousselin B, Ayral X, Edouard-Noë1 R, Dougados M, Ravaud P. Osteoarthritis of the hip: agreement between joint space width measurements on standing and supine conventional radiographs. Ann Rheum Dis1998;57:519–23.[Abstract/Free Full Text]
  38. Scott DL, Gishen P. Radiological assessment of hip osteoarthritis. Lancet1999;353:87–8.[Medline]
Submitted 12 June 2000; revised version accepted 25 October 2000.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
A. B. Sevrukov, J. M. Bland, and G. T. Kondos
Serial Electron Beam CT Measurements of Coronary Artery Calcium: Has Your Patient's Calcium Score Actually Changed?
Am. J. Roentgenol., December 1, 2005; 185(6): 1546 - 1553.
[Abstract] [Full Text] [PDF]


Home page
J Bone Joint Surg BrHome page
S. Jacobsen, S. Sonne-Holm, K. Soballe, P. Gebuhr, and B. Lund
Joint space width in dysplasia of the hip: A CASE-CONTROL STUDY OF 81 ADULTS FOLLOWED FOR TEN YEARS
J Bone Joint Surg Br, April 1, 2005; 87-B(4): 471 - 477.
[Abstract] [Full Text] [PDF]


Home page
Ann Rheum DisHome page
M Reijman, J M W Hazes, H A P Pols, R M D Bernsen, B W Koes, and S M A Bierma-Zeinstra
Validity and reliability of three definitions of hip osteoarthritis: cross sectional and longitudinal approach
Ann Rheum Dis, November 1, 2004; 63(11): 1427 - 1433.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (19)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Auleley, G.-R.
Right arrow Articles by Ravaud, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Auleley, G.-R.
Right arrow Articles by Ravaud, P.
Related Collections
Right arrow Osteoarthritis and Cartilage
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?